Solar output estimate · PDF report
Gridhours Solar Report
Solar output estimates, presented with precision
Every solar decision starts with one number: how much electricity the system will produce. Get that estimate for any site on Earth, sized to a household’s use or to your own design, and hand it over as a polished report with your brand and every assumption in view.
- PVGIS 5.3 · 2005–2023 data
- Fixed and 3 tracker types
- Branded PDF report
- Private: built in your browser
Define the site to see the solar output estimate.
kWh in the first year
Your solar output estimate, month by month
Four sites, one system: 1 kWp at the best angles.
PVGIS 5.3 output of 1 kWp of crystalline silicon panels on a roof, at the best tilt and direction, with horizon shading and 14% losses. Multiply by the system size for any design.
| Site | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | Year |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| London | 41 | 53 | 85 | 111 | 115 | 117 | 119 | 107 | 93 | 69 | 48 | 37 | 997 |
| Berlin | 32 | 55 | 89 | 117 | 126 | 126 | 124 | 117 | 101 | 71 | 39 | 29 | 1,026 |
| Sydney | 150 | 121 | 110 | 87 | 71 | 54 | 66 | 89 | 114 | 137 | 146 | 159 | 1,305 |
| Phoenix | 135 | 136 | 164 | 165 | 162 | 147 | 139 | 142 | 143 | 151 | 135 | 124 | 1,743 |
Inside the report
Up to five pages, every assumption in view.
Cover
Your brand and colour, the client and site, a map of the location and the three figures that matter.
System and generation
The full specification, a month-by-month chart and a table of output, daily averages and coverage of use.
Recommendations (optional)
What the numbers suggest: sizing, orientation, inverter, seasons and survey checks, with facts about the site.
Lifetime and losses
Output year by year with ageing, savings and payback if you entered a price, and each loss behind the estimate.
Method and sources
How the estimate was made, its data and limits, your notes, and links back to Gridhours.com.
Built for installers
Your name on the work.
Your brand throughout. Company name, contact line, logo and colour sit on every page of the report. Your company details stay in this browser for the next client, and nowhere else.
Private by design. The PDF is assembled on your device. The client’s name, address and your notes are never uploaded. Only the site location, rounded to about 10 km, and the panel settings go to the estimate service.
Free, without an account. No sign-up, no watermark, no limit on reports. Any panel brand, any inverter, any country with land under the sun.
The settings, explained
What each choice does to the estimate.
- Mounting
- Roof panels run warmer than panels on an open rack, and warm panels produce less. The setting changes the temperature model for fixed panels; trackers are modelled as open-rack.
- Tracking
- A single-axis tracker turns the panels east to west through the day on a tilted axis; a vertical-axis tracker turns around an upright axis; a two-axis tracker follows the sun in both directions. Each makes more than fixed panels, at more cost.
- Panel technology
- Crystalline silicon covers almost all rooftop panels. CIS and CdTe are thin-film technologies that respond differently to heat and to the colour of the light.
- Tilt and direction
- “Best” lets PVGIS find the angle, and direction if you allow it, that gives the most electricity over the year. Choose your own to match a roof.
- Horizon shading
- Hills and mountains that hide the sun near sunrise and sunset, from a terrain model. Trees and buildings nearby are not in it.
- System losses
- Everything between the panels and the meter except heat and light angle: cables, inverter, dirt, mismatch, downtime. PVGIS recommends 14%.
- Inverter AC size
- When the panels’ DC rating is larger than the inverter, the inverter caps the power on the brightest hours. The report works out that clipping from hourly PVGIS data.
- Ageing
- Panels lose a little output each year. 0.5% a year is the median of measured rates (NREL); use your manufacturer’s warranty figure if you prefer.
How the solar estimate is made
An hour-by-hour model, averaged over nineteen years.
The estimate comes from PVGIS 5.3, the Photovoltaic Geographical Information System of the European Commission’s Joint Research Centre. For the site, it takes sunlight measured by satellite, or a global weather model where the satellites do not reach, for every hour from 2005 to 2023, and models the panels: the sun’s angle on them, their temperature, the colour of the light and the shade of the horizon.
PVGIS returns the output of 1 kWp. The report scales it to your system size and losses, takes off inverter clipping if you give an inverter size, and applies ageing year by year. Sizing to usage runs the sum the other way, from the kWh you need to the kWp that provides it, rounded up to whole panels.
It is an estimate of an average year, not a guarantee. Weather varies from year to year, and the model cannot see the trees, chimneys or neighbouring buildings around a particular roof. For a contract, confirm the figures with a site survey.
Gridhours Solar Report, PVWatts and PVGIS
Three ways to a solar estimate.
All three estimate an average year from similar inputs. The Solar Report adds sizing to a household’s use, a side-by-side tracker comparison and a branded PDF report.
| Feature | Gridhours Solar Report | PVWatts | PVGIS |
|---|---|---|---|
| Published by | Gridhours.com, using PVGIS 5.3 | US National Renewable Energy Laboratory (NREL) | European Commission Joint Research Centre |
| Sunlight data | PVGIS satellite data where available, ERA5 weather model elsewhere; 2005–2023 | NREL National Solar Radiation Database | Satellite data where available, ERA5 elsewhere; 2005–2023 |
| Tracking | Fixed and three tracker types, compared side by side | Fixed and trackers | Fixed and trackers |
| Inverter clipping | From hourly data, for your inverter size | DC-to-AC ratio input | Hourly data to download |
Questions
About the estimate and the report.
How accurate is the solar output estimate?
It is as good as the model behind it: PVGIS 5.3 from the European Commission’s Joint Research Centre, which works hour by hour from satellite or weather-model sunlight data for 2005 to 2023. It describes an average year. Real years vary around it: in London, a single year differs from the average by about 4%. Site-specific shade from trees or nearby buildings is not modelled, so a site survey remains the final word.
What does the PDF solar report include?
Up to five pages: a cover with your brand, the client, the headline figures and a map of the site; the system and its month-by-month generation; recommendations and facts drawn from the estimate, if you include them; lifetime output with ageing, any savings you entered, and the losses behind the estimate; and the method, sources and your notes. It is built in your browser and downloads at once.
Can installers put their own brand on the report?
Yes. Add your company name, contact details, logo (PNG or JPG) and brand colour, and they appear on every page. Your company details are remembered in this browser for the next report; you can clear them at any time.
Is client information stored anywhere?
No. The client’s name, address, your logo and your notes never leave the browser: the PDF is assembled on your device. The only thing sent to our server, and on to PVGIS, is the location, rounded to about 10 km, and the panel settings.
How do I size a system to a home’s electricity use?
Divide the yearly use by what 1 kW of panels produces at the site. A typical UK home uses 2,500 kWh a year (Ofgem, 2026). In London, 1 kW of panels at the best angles makes about 997 kWh, so about 2.5 kW covers that over a year. Choose “Size to usage” and the report does this with your figures, month by month if you enter twelve readings.
How much do shading and roof direction change the output?
Direction matters less than many expect. In New York, a 35° roof facing east makes 79% of what a south-facing one makes over a year, facing west 75% and facing north 48% (PVGIS). Distant hills and mountains are included when horizon shading is on; nearby trees and buildings are not, so allow for them in the losses.
What is the difference between fixed and tracking systems?
Trackers turn the panels to follow the sun. A two-axis tracker in London makes 31% more than fixed panels at the best angles, and 42% more in Phoenix; a single-axis tracker makes 28% and 38% more. Homes almost always use fixed panels; trackers are common on large ground-mounted farms.
Why does solar output change from month to month?
Day length and the height of the sun change with the seasons, and so does the weather. In London, 1 kW of fixed panels makes 119 kWh in July and 37 kWh in December. Closer to the equator the year is flatter: in Sydney the range is 54 to 159 kWh.
How does the Gridhours Solar Report compare with PVWatts?
PVWatts is the US National Renewable Energy Laboratory’s calculator, built on its National Solar Radiation Database. The Gridhours Solar Report uses PVGIS 5.3, the European Commission’s model, with satellite data across Europe, Africa and much of Asia and a global weather model elsewhere. Both estimate an average year from similar inputs. The Solar Report adds sizing to a household’s use, tracker comparison, inverter clipping from hourly data and a branded PDF.
How much does output fall as panels age?
The report assumes 0.5% a year unless you change it: the median of about 2,000 measured degradation rates reviewed by NREL (Jordan and Kurtz, 2013). At that rate a system makes 89% of its first-year output in year 25. Use the rate from the panel manufacturer’s warranty if you prefer.
Sources
Where the numbers come from.
- European Commission Joint Research Centre, PVGIS 5.3: output, tracking, losses and hourly data. PVGIS © European Communities, 2001-2026.
- PVGIS non-interactive service: inputs for grid-connected and tracking systems
- Jordan and Kurtz, Photovoltaic Degradation Rates: An Analytical Review (NREL, 2013): median ageing of 0.5% a year.
- Ofgem, energy price cap update from 1 July 2026: 2026 Typical Domestic Consumption Values
- NREL, PVWatts: weather data from the National Solar Radiation Database
An estimate for planning and proposals, not a guarantee of output. Confirm with a site survey before contract.