Global Power Plant Directory121,919 plants · 219 countries & territories

Home / Tools / Solar Report

Solar output estimate · PDF report

Gridhours Solar Report

Solar output estimates, presented with precision

Every solar decision starts with one number: how much electricity the system will produce. Get that estimate for any site on Earth, sized to a household’s use or to your own design, and hand it over as a polished report with your brand and every assumption in view.

  • PVGIS 5.3 · 2005–2023 data
  • Fixed and 3 tracker types
  • Branded PDF report
  • Private: built in your browser
01 Define the site

No site yet. Search, choose a city or click the map.

02 Shape the system
Losses, inverter, ageing and savings

Losses cover cables, the inverter, dirt, mismatch and availability; PVGIS recommends 14%. Add nearby shade here. The inverter size, if given, adds clipping worked out from hourly PVGIS data for 2021–2023.

03 Deliver the report

Built on your device. Client details, your logo and notes are never uploaded.

Define the site to see the solar output estimate.

Your solar output estimate, month by month

Four sites, one system: 1 kWp at the best angles.

PVGIS 5.3 output of 1 kWp of crystalline silicon panels on a roof, at the best tilt and direction, with horizon shading and 14% losses. Multiply by the system size for any design.

SiteJanFebMarAprMayJunJulAugSepOctNovDecYear
London41538511111511711910793694837997
Berlin3255891171261261241171017139291,026
Sydney15012111087715466891141371461591,305
Phoenix1351361641651621471391421431511351241,743

Inside the report

Up to five pages, every assumption in view.

  1. Cover

    Your brand and colour, the client and site, a map of the location and the three figures that matter.

  2. System and generation

    The full specification, a month-by-month chart and a table of output, daily averages and coverage of use.

  3. Recommendations (optional)

    What the numbers suggest: sizing, orientation, inverter, seasons and survey checks, with facts about the site.

  4. Lifetime and losses

    Output year by year with ageing, savings and payback if you entered a price, and each loss behind the estimate.

  5. Method and sources

    How the estimate was made, its data and limits, your notes, and links back to Gridhours.com.

Built for installers

Your name on the work.

Your brand throughout. Company name, contact line, logo and colour sit on every page of the report. Your company details stay in this browser for the next client, and nowhere else.

Private by design. The PDF is assembled on your device. The client’s name, address and your notes are never uploaded. Only the site location, rounded to about 10 km, and the panel settings go to the estimate service.

Free, without an account. No sign-up, no watermark, no limit on reports. Any panel brand, any inverter, any country with land under the sun.

The settings, explained

What each choice does to the estimate.

Mounting
Roof panels run warmer than panels on an open rack, and warm panels produce less. The setting changes the temperature model for fixed panels; trackers are modelled as open-rack.
Tracking
A single-axis tracker turns the panels east to west through the day on a tilted axis; a vertical-axis tracker turns around an upright axis; a two-axis tracker follows the sun in both directions. Each makes more than fixed panels, at more cost.
Panel technology
Crystalline silicon covers almost all rooftop panels. CIS and CdTe are thin-film technologies that respond differently to heat and to the colour of the light.
Tilt and direction
“Best” lets PVGIS find the angle, and direction if you allow it, that gives the most electricity over the year. Choose your own to match a roof.
Horizon shading
Hills and mountains that hide the sun near sunrise and sunset, from a terrain model. Trees and buildings nearby are not in it.
System losses
Everything between the panels and the meter except heat and light angle: cables, inverter, dirt, mismatch, downtime. PVGIS recommends 14%.
Inverter AC size
When the panels’ DC rating is larger than the inverter, the inverter caps the power on the brightest hours. The report works out that clipping from hourly PVGIS data.
Ageing
Panels lose a little output each year. 0.5% a year is the median of measured rates (NREL); use your manufacturer’s warranty figure if you prefer.

How the solar estimate is made

An hour-by-hour model, averaged over nineteen years.

The estimate comes from PVGIS 5.3, the Photovoltaic Geographical Information System of the European Commission’s Joint Research Centre. For the site, it takes sunlight measured by satellite, or a global weather model where the satellites do not reach, for every hour from 2005 to 2023, and models the panels: the sun’s angle on them, their temperature, the colour of the light and the shade of the horizon.

PVGIS returns the output of 1 kWp. The report scales it to your system size and losses, takes off inverter clipping if you give an inverter size, and applies ageing year by year. Sizing to usage runs the sum the other way, from the kWh you need to the kWp that provides it, rounded up to whole panels.

It is an estimate of an average year, not a guarantee. Weather varies from year to year, and the model cannot see the trees, chimneys or neighbouring buildings around a particular roof. For a contract, confirm the figures with a site survey.

Gridhours Solar Report, PVWatts and PVGIS

Three ways to a solar estimate.

All three estimate an average year from similar inputs. The Solar Report adds sizing to a household’s use, a side-by-side tracker comparison and a branded PDF report.

FeatureGridhours Solar ReportPVWattsPVGIS
Published byGridhours.com, using PVGIS 5.3US National Renewable Energy Laboratory (NREL)European Commission Joint Research Centre
Sunlight dataPVGIS satellite data where available, ERA5 weather model elsewhere; 2005–2023NREL National Solar Radiation DatabaseSatellite data where available, ERA5 elsewhere; 2005–2023
TrackingFixed and three tracker types, compared side by sideFixed and trackersFixed and trackers
Inverter clippingFrom hourly data, for your inverter sizeDC-to-AC ratio inputHourly data to download

Questions

About the estimate and the report.

How accurate is the solar output estimate?

It is as good as the model behind it: PVGIS 5.3 from the European Commission’s Joint Research Centre, which works hour by hour from satellite or weather-model sunlight data for 2005 to 2023. It describes an average year. Real years vary around it: in London, a single year differs from the average by about 4%. Site-specific shade from trees or nearby buildings is not modelled, so a site survey remains the final word.

What does the PDF solar report include?

Up to five pages: a cover with your brand, the client, the headline figures and a map of the site; the system and its month-by-month generation; recommendations and facts drawn from the estimate, if you include them; lifetime output with ageing, any savings you entered, and the losses behind the estimate; and the method, sources and your notes. It is built in your browser and downloads at once.

Can installers put their own brand on the report?

Yes. Add your company name, contact details, logo (PNG or JPG) and brand colour, and they appear on every page. Your company details are remembered in this browser for the next report; you can clear them at any time.

Is client information stored anywhere?

No. The client’s name, address, your logo and your notes never leave the browser: the PDF is assembled on your device. The only thing sent to our server, and on to PVGIS, is the location, rounded to about 10 km, and the panel settings.

How do I size a system to a home’s electricity use?

Divide the yearly use by what 1 kW of panels produces at the site. A typical UK home uses 2,500 kWh a year (Ofgem, 2026). In London, 1 kW of panels at the best angles makes about 997 kWh, so about 2.5 kW covers that over a year. Choose “Size to usage” and the report does this with your figures, month by month if you enter twelve readings.

How much do shading and roof direction change the output?

Direction matters less than many expect. In New York, a 35° roof facing east makes 79% of what a south-facing one makes over a year, facing west 75% and facing north 48% (PVGIS). Distant hills and mountains are included when horizon shading is on; nearby trees and buildings are not, so allow for them in the losses.

What is the difference between fixed and tracking systems?

Trackers turn the panels to follow the sun. A two-axis tracker in London makes 31% more than fixed panels at the best angles, and 42% more in Phoenix; a single-axis tracker makes 28% and 38% more. Homes almost always use fixed panels; trackers are common on large ground-mounted farms.

Why does solar output change from month to month?

Day length and the height of the sun change with the seasons, and so does the weather. In London, 1 kW of fixed panels makes 119 kWh in July and 37 kWh in December. Closer to the equator the year is flatter: in Sydney the range is 54 to 159 kWh.

How does the Gridhours Solar Report compare with PVWatts?

PVWatts is the US National Renewable Energy Laboratory’s calculator, built on its National Solar Radiation Database. The Gridhours Solar Report uses PVGIS 5.3, the European Commission’s model, with satellite data across Europe, Africa and much of Asia and a global weather model elsewhere. Both estimate an average year from similar inputs. The Solar Report adds sizing to a household’s use, tracker comparison, inverter clipping from hourly data and a branded PDF.

How much does output fall as panels age?

The report assumes 0.5% a year unless you change it: the median of about 2,000 measured degradation rates reviewed by NREL (Jordan and Kurtz, 2013). At that rate a system makes 89% of its first-year output in year 25. Use the rate from the panel manufacturer’s warranty if you prefer.

Sources

Where the numbers come from.

  1. European Commission Joint Research Centre, PVGIS 5.3: output, tracking, losses and hourly data. PVGIS © European Communities, 2001-2026.
  2. PVGIS non-interactive service: inputs for grid-connected and tracking systems
  3. Jordan and Kurtz, Photovoltaic Degradation Rates: An Analytical Review (NREL, 2013): median ageing of 0.5% a year.
  4. Ofgem, energy price cap update from 1 July 2026: 2026 Typical Domestic Consumption Values
  5. NREL, PVWatts: weather data from the National Solar Radiation Database

An estimate for planning and proposals, not a guarantee of output. Confirm with a site survey before contract.